699-416

SUB-APPENDIX F13 - NAC FM WEIGHTED RADIOMETRIC CONVERSION FACTORS PER FILTER COMBINATION
(for calibration testing performed with the sphere or uv box, as indicated)



 
 
 
 
Integral of SpRad/pA*wind*optics*filt1*filt2*qe over wl (weights the SpRad*wind by the bandpasses of the components seeing the light)
Integral of optics*filt1*filt2*qe over wl (weighting function to divide out)
Weighted Average of SpRad/pA Transmitted Through the Chamber Window (Integral #1 / Integral #2)
COMBO #
FILTER 1
FILTER 2
EQUPT
Integral #1
Integral #2
Result
1
BL1
CL2
SPHR
15.207
87.732
0.173334701
2
CL1
BL2
SPHR
3.8323
19.139
0.200235122
3
CL1
CB1
SPHR
3.9736
41.327
0.096150217
4
CL1
CB2
SPHR
1.6521
18.375
0.089910204
5
CL1
CB3
SPHR
0.72947
3.7239
0.195888719
6
CL1
CL2
SPHR
124.69
953.3
0.13079828
7
CL1
GRN
SPHR
25.853
238.66
0.108325652
8
CL1
IR1
SPHR
24.537
265.05
0.092574986
9
CL1
IR3
SPHR
0.68463
7.1083
0.096314168
10
CL1
MT1
SPHR
0.68463
7.1083
0.096314168
11
CL1
MT2
SPHR
0.72888
7.661
0.095141626
12
CL1
MT3
SPHR
0.91449
7.3703
0.124077717
13
CL1
UV3
UVBOX
39.41
0.071478
551.3584599
14
HAL
CL2
SPHR
1.5892
17.87
0.08893117
15
HAL
IR3
SPHR
1.1746E-05
1.3029E-04
0.090152736
16
HAL
MT3
SPHR
0
0
*
17
IR2
CL2
SPHR
10.64
92.966
0.114450444
18
IR2
IR1
SPHR
2.9242
30.523
0.095803165
19
IR2
IR3
SPHR
4.0041
29.143
0.137394915
20
IR4
CL2
SPHR
5.4392
8.5112
0.639063822
21
IR4
IR3
SPHR
3.8377
7.0243
0.546346255
22
IRP0
CB2
SPHR
1.5839
17.617
0.089907476
23
IRP0
CB3
SPHR
0.73976
3.7763
0.195895453
24
IRP0
CL2
SPHR
55.887
501.25
0.111495262
25
IRP0
IR1
SPHR
23.531
254.4
0.092496069
26
IRP0
IR3
SPHR
12.359
54.423
0.227091487
27
IRP0
MT2
SPHR
0.69162
7.2694
0.095141277
28
IRP0
MT3
SPHR
0.91615
7.3836
0.12407904
29
P0
BL2
SPHR
2.228
11.137
0.200053874
30
P0
CB1
SPHR
2.6515
27.624
0.095985375
31
P0
CB2
SPHR
1.3547
15.068
0.089905761
32
P0
CL2
SPHR
60.043
510.79
0.117549286
33
P0
GRN
SPHR
16.63
153.63
0.108247087
34
P0
IR1
SPHR
16.136
174.48
0.092480514
35
P0
MT1
SPHR
0.45965
4.7724
0.096314223
36
P0
MT2
SPHR
0.58586
6.1578
0.095141122
37
P0
UV3
UVBOX
10334
21.75
475.1264368
38
P120
BL2
SPHR
2.228
11.137
0.200053874
39
P120
CB1
SPHR
2.6515
27.624
0.095985375
40
P120
CB2
SPHR
1.3547
15.068
0.089905761
41
P120
CL2
SPHR
60.043
510.79
0.117549286
42
P120
GRN
SPHR
16.63
153.63
0.108247087
43
P120
IR1
SPHR
16.136
174.48
0.092480514
44
P120
MT1
SPHR
0.45965
4.7724
0.096314223
45
P120
MT2
SPHR
0.58586
6.1578
0.095141122
46
P120
UV3
UVBOX
10334
21.75
475.1264368
47
P160
BL2
SPHR
2.228
11.137
0.200053874
48
P60
CB1
SPHR
2.6515
27.624
0.095985375
49
P60
CB2
SPHR
1.3547
15.068
0.089905761
50
P60
CL2
SPHR
60.043
510.79
0.117549286
51
P60
GRN
SPHR
16.63
153.63
0.108247087
52
P60
IR1
SPHR
16.136
174.48
0.092480514
53
P60
MT1
SPHR
0.45965
4.7724
0.096314223
54
P60
MT2
SPHR
0.58586
6.1578
0.095141122
55
P60
UV3
UVBOX
10334
21.75
475.1264368
56
RED
CB1
SPHR
3.4597
36.014
0.096065419
57
RED
CL2
SPHR
27.217
279.91
0.097234825
58
RED
GRN
SPHR
9.6034
94.351
0.101783765
59
RED
IR1
SPHR
8.0649
81.353
0.099134635
60
RED
MT1
SPHR
0.60041
6.2341
0.096310614
61
UV1
CL2
UVBOX
8816
9.527
925.370001
62
UV2
CL2
UVBOX
13851
15.948
868.510158

SAMPLE CALCULATION (FOR DATA TAKEN WITH THE SPHERE) - Shows an example of a calculation for the clear 1/clear 2 filter combination with data at every 50 nm (result slightly varies from value shown above). The values shown above were calculated from data interpolated at every 0.1 nm.

SAMPLE CALCULATION (FOR DATA TAKEN WITH THE UV BOX) - Shows an example of a calculation for the uv1/cl2 filter combination with data at every 50 nm (result slightly varies from value shown above). The values shown above were calculated from data interpolated at every 0.1 nm.

Spectral Radiance (SpRad) units are in nw/cm2 /sr/nm. With calibration testing performed with the sphere, each picoamp (pA) of measured light output provides the specified amount of SpRad units.

EQUPT - Equipment : During light transfer calibration testing, either the sphere(SPHR) or the uv box (UVBOX) was used to provide the flat-field light source, as designated in the table. Each, of course, has its own radiometric conversion factors.

There are a total of 62 filter combinations.

* - Calculation could not be made (filter bandpass measurements do not intersect).


HOME BACK